如何給真空甩帶爐換氣
由于真空甩帶爐適用(yong)(yong)(yong)于各(ge)大科研(yan)院所(suo)(suo)、材料研(yan)究(jiu)所(suo)(suo)內所(suo)(suo)有(you)操(cao)作(zuo)使用(yong)(yong)(yong)設備的人員。故(gu)在操(cao)作(zuo)使用(yong)(yong)(yong)中要正確規(gui)范(fan)的操(cao)作(zuo),以保證該設備正常運轉。今(jin)天八佳科技就和(he)大家說下氣體的。
先是(shi)要卸下(xia)裝(zhuang)氣(qi)體(ti)的(de)空(kong)(kong)瓶。順時針(zhen)(zhen)轉動空(kong)(kong)鋼瓶上(shang)的(de)放氣(qi)閥(fa),使之關閉。接著逆時針(zhen)(zhen)旋動減(jian)(jian)(jian)壓(ya)(ya)閥(fa)上(shang)的(de)小閥(fa)至“shut”利(li)用扳(ban)手逆時針(zhen)(zhen)擰動連接鋼瓶與減(jian)(jian)(jian)壓(ya)(ya)閥(fa)之間的(de)螺絲直(zhi)至將(jiang)兩(liang)者(zhe)分開(kai),將(jiang)減(jian)(jian)(jian)壓(ya)(ya)閥(fa)置(zhi)于不易掉落之地,把空(kong)(kong)鋼瓶小心挪(nuo)出(chu),置(zhi)于閑處。取下(xia)真(zhen)空(kong)(kong)甩(shuai)帶爐上(shang)的(de)空(kong)(kong)瓶后接著就(jiu)(jiu)是(shi)裝(zhuang)新(xin)瓶。將(jiang)新(xin)鋼瓶挪(nuo)入原空(kong)(kong)瓶處,并裝(zhuang)上(shang)減(jian)(jian)(jian)壓(ya)(ya)閥(fa),確保連接牢靠不漏氣(qi)。將(jiang)鋼瓶的(de)放氣(qi)閥(fa)逆時針(zhen)(zhen)擰開(kai),減(jian)(jian)(jian)壓(ya)(ya)閥(fa)“shut”。下(xia)來待到裝(zhuang)好就(jiu)(jiu)是(shi)開(kai)電源了。這時需(xu)將(jiang)對面墻壁上(shang)左邊的(de)電源閘刀向上(shang)撥至“on”。
真空甩帶爐的(de)(de)洗(xi)氣過程(cheng)是個比較復雜且重要的(de)(de)過程(cheng),就此我們(men)要詳細的(de)(de)做個講解。
當按(an)下機械泵電源按(an)鈕,等待(dai)2分鐘后抽出真空(kong)甩(shuai)帶爐的機械泵拉(la)桿(gan)。接著開充(chong)(chong)(chong)氣(qi)閥(fa),將充(chong)(chong)(chong)氣(qi)閥(fa)(甩(shuai)帶爐腔體右懸臂下)逆時(shi)(shi)針旋轉(zhuan)90度,使之(zhi)平行于該(gai)裝置。按(an)下“充(chong)(chong)(chong)氣(qi)Ⅰ”。待(dai)氬(ya)氣(qi)罐氣(qi)壓表(前面板(ban)左下)指針指向“-0.01MPa”。在關充(chong)(chong)(chong)氣(qi)閥(fa)時(shi)(shi),需要順時(shi)(shi)針旋轉(zhuan)充(chong)(chong)(chong)氣(qi)閥(fa)90度,使之(zhi)與該(gai)裝置垂直(zhi)。
在(zai)給氬氣(qi)(qi)(qi)(qi)罐(guan)(guan)充(chong)氣(qi)(qi)(qi)(qi)時(shi),要順(shun)時(shi)針(zhen)旋(xuan)(xuan)轉(zhuan)減壓閥(fa)(fa)(fa)(fa)上的(de)小閥(fa)(fa)(fa)(fa)至“open”,觀察真空甩帶(dai)爐的(de)氬氣(qi)(qi)(qi)(qi)罐(guan)(guan)氣(qi)(qi)(qi)(qi)壓表(biao)為“0.08MPa”時(shi),逆(ni)時(shi)針(zhen)旋(xuan)(xuan)轉(zhuan)小閥(fa)(fa)(fa)(fa)至“shut”。再開啟充(chong)氣(qi)(qi)(qi)(qi)閥(fa)(fa)(fa)(fa),將充(chong)氣(qi)(qi)(qi)(qi)閥(fa)(fa)(fa)(fa)(甩帶(dai)爐腔(qiang)體右懸(xuan)臂(bei)下)逆(ni)時(shi)針(zhen)旋(xuan)(xuan)轉(zhuan)90度,使之(zhi)平行于該裝置。待氬氣(qi)(qi)(qi)(qi)罐(guan)(guan)氣(qi)(qi)(qi)(qi)壓表(biao)指向“-0.01MPa”時(shi),關充(chong)氣(qi)(qi)(qi)(qi)閥(fa)(fa)(fa)(fa)。需要順(shun)時(shi)針(zhen)旋(xuan)(xuan)轉(zhuan)充(chong)氣(qi)(qi)(qi)(qi)閥(fa)(fa)(fa)(fa)90度,使之(zhi)與該裝置垂直。
當真空甩帶爐(lu)換氣(qi)(qi)結束,操作者要順時(shi)針旋(xuan)轉減壓閥(fa)上的小閥(fa)至“open”,觀察氬氣(qi)(qi)罐氣(qi)(qi)壓表為“0.08MPa”時(shi),關閉“充氣(qi)(qi)Ⅰ”,并將(jiang)機(ji)械泵拉桿推進,關閉機(ji)械泵電源(yuan)(yuan)按鈕。接著,關閉電源(yuan)(yuan),將(jiang)總電源(yuan)(yuan)閘刀(dao)拉下至“off”。
好了,以上就是為大家講解該如何給真空甩帶爐換氣的步驟。如(ru)果(guo)大(da)家還(huan)有不懂,歡(huan)迎隨(sui)時來(lai)電咨詢。

免責聲明:本站部分圖(tu)片和文(wen)字來源于網絡收集整理,僅供學習交流,版權歸原(yuan)作者(zhe)所有,并不代表我站觀點。本站將不承擔任何法律責任,如果有侵犯到您的權利,請及時(shi)聯系我們刪除。
- 上一篇:真空熔煉爐操作安全指南
- 下一篇:熔鹽電解爐裝置工藝